-
Honeywell TC809A1059 FlashScan Monitor Module is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices.
- $138.79
$169.06- $138.79
- Unit price
- per
-
Edwards EST M500CFS Addressable Intelligent Control Module
- $75.00
$99.00- $75.00
- Unit price
- per
-
Johnson Controls M300RJ Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows thedry contact to be activated, either manually or through panel programming, on a select basis.....
- $139.90
$169.00- $139.90
- Unit price
- per
-
The TC810R1024(CDN) Addressable Relay Module provides the system with a dry-contact output for activating a variety of auxiliary devices, such as fans, dampers, control equipment, etc. Addressability allows the dry contact to be activated, either manually or through panel programming, on a select basis....
- $135.00
$156.70- $135.00
- Unit price
- per
-
HONEYWELL TC810A1056 INTELLIGENT CONTROL MODULE
- $99.00
$129.00- $99.00
- Unit price
- per
-
JOHNSON CONTROLS M500MJ MINITOR MODULE
- $95.00
$128.00- $95.00
- Unit price
- per
-
The Johnson Controls M510CJ is an addressable Control Relay Module.
- $119.00
$139.00- $119.00
- Unit price
- per
-
Uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC) A flashing LED indicates that the module is in communication...
- $77.89
$109.60- $77.89
- Unit price
- per
-
Mircom MIX-M500X Isolator Module The M500X Isolator Module is a standard-sized module that enables part of the communications loop to continue operating when a short circuit occurs on it. An LED indicator blinks in the normal condition and turns on during a short circuit...
- $60.00
- $60.00
- Unit price
- per
-
Addressable monitor modules AMM-4SF feature a single Style D, Class A initiating device circuit. They may also be configured as a Style B, Class B initiating circuit with an end-of-line resistor. These modules provide an address for a group of conventional 2-wire smoke detectors....
- $98.00
- $98.00
- Unit price
- per
-
The AOM-2RF is an addressable output relay control module. The AOM-2RF allows a Gamewell-FCI addressable fire alarm control panel to switch discrete relay contacts via software code commands. The AOM-2RF is compatible with the E3 Series, S3 Series, and 7100 Series Fire Alarm Control...
- $128.00
- $128.00
- Unit price
- per
-
The Gamewell-FCI Velociti® Series addressable output supervised control module allows an Gamewell-FCI analog addressable fire alarm control to switch an external power supply, such as a DC supply or audio amplifier (up to 80 VRMS) to notification appliances.
- $112.00
- $112.00
- Unit price
- per
-
4XZM zone relay modules provide four Form C relay contacts to fire alarm control panels (FACPs).Notifier 4XZM Zone Relay Module provides Form-C general alarm and trouble contacts and the following Form-C relays: a) Zone 1.b) Zone 2.c) Zone 3.d) Zone 4. The 4XZM includes...
- $120.00
- $120.00
- Unit price
- per
-
Gamewell-FCI AMM-4 Fire Alarm Interface Module. The Addressable Monitor Module AMM-4 features a single Style D, Class A circuit. It may also be configured as a Style B, Class B initiating circuit with end of line resistor. This module provides an address for any...
- $75.00
$88.00- $75.00
- Unit price
- per
-
The Honeywell TC810N1013 Supervised Control Module is intended for use in intelligent two-wire systems where the individual address of each module is selected using built-in rotary decade switches.
- $129.00
$159.00- $129.00
- Unit price
- per
-
The Honeywell TC811A Fault Isolator Module is used with the Honeywell Intelligent Fire Alarm Control Panels (FACP) CLIP and FlashScan SLC’s to protect the system against wire-to-wire short circuits.
- $75.00
$95.00- $75.00
- Unit price
- per
-
Johnson Controls J5351 Detector Intelligent Thermall w/Flash Scan
- $109.00
$139.00- $109.00
- Unit price
- per
-
Johnson Controls M302MJ Addressable Monitor Module is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit.
- $169.00
$200.00- $169.00
- Unit price
- per
-
The Johnson Controls M500XJ Fault Isolator Module is used with the IFC Intelligent Fire Alarm Control Panels (FACP) to protect the system against wire-to-wire short circuits on the SLC loops.
- $75.00
$95.00- $75.00
- Unit price
- per
-
The Notifier CMX-2 Control Module is an addressable module that supervises and switches power to a Notification Appliance Circuit (NAC). The Notifier CMX-2 circuit can be wire as an NFPA Style Y or Style Z NAC. Alternately, the CMX can be employ as a...
- $149.00
$199.00- $149.00
- Unit price
- per